    Brand Name : HiYi
    Model Number : XM-R-O2
    Certification : CE/RoHS
    Price : USD 100-500/pcs
    Payment Terms : L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 set/month
    Delivery Time : 3-7 days
    • Product Details
    • Company Profile

    City Sensor 3000MAh Oxygen Portable O2 Gas Detector Analyzer

    HiYi ATEX Certified Internal Pump 3000 mAh City Sensor Oxygen Leak Detection Portable O2 Gas Analyzer

    Portable Gas Detector

    O2 Oxygen


    ABOUT OXYGEN (O2)

    Oxygen (O2) is one of the main components for air and occurs normally at 20.9% in the atmosphere at sea level. In the air it is mainly produced by algae and plants. Oxygen is essential for life, particularly human life.


    If the Oxygen level or pressure is too low we asphyxiate and quickly and die. Typically at sea level 12% or lower concentration.
    If the O2 level or pressure is too high then the level of the gas radicals rapidly damage cells resulting in blindness, seizures, respiratory distress and bleeding. Typically at sea level 45% or higher concentrations. This is the reason Oxygen therapy in hospitals can be controversial and should only be short-term.
    Higher than normal levels will also greatly accelerate fires and explosions so it is normal to alarm at levels above 23% at sea level.


    Accurate oxygen (O2) level measurements are essential in preventing injury or death in situations where safe levels may be compromised. Oxygen gas detection instruments will typically trigger an alarm when the oxygen level drops below 19.5% volume, the OSHA-mandated level. The most common use of oxygen gas detection is in confined spaces – totally or partially closed areas generally not designed to be permanently occupied. It is essential that an O2 gas sample is drawn prior to entering these spaces, and is continuously monitored after entry.


    OVERVIEW

    XM-E- Pump Portable Gas Detector is a continuous monitoring of a variety of single gas detection equipment.

    This product is suitable for environmental monitoring, industrial production and other harmful gases working environment, which can effectively protect the health and safety of staff is not compromised.It meets European standard gas detector.


    City Sensor 3000MAh Oxygen Portable O2 Gas Detector Analyzer


    FEATURES & BENEFITS
    • Intelligent Probe design;convenient calibration and maintenance
    • Fault, Warning, operator error, alarm will be smart tips
    • Built-in CF calibration coefficients (VOC measurements only valid)
    • With audible alarm, visual alarm function, the status bar also displays alarm status
    • Full-color 3.5-inch TFT screen, color LCD display and intuitive
    • Can be both digital and curve display of gas concentration in two ways
    • With USB communication port, you can speed 9600 bytes to communicate directly with the computer
    • With test record function, can store a month's measurement data and instrument or computer can view the data
    • Memory capacity is 2M,can store more than 90,000 pieces of data
    • With alarm recording function, you can record the last four times the alarm time and type
    • With calibration record; can record the last four times the size of the calibration time span
    • High-capacity lithium battery-powered, rechargeable, low battery automatic shutdown
    • Can be set high reported, underreporting, TWA, STEL, shutdown time, pump speed, etc.
    • Indicate way : LCD display real-time concentration ,LED ,buzzer alarm

    City Sensor 3000MAh Oxygen Portable O2 Gas Detector Analyzer

    City Sensor 3000MAh Oxygen Portable O2 Gas Detector Analyzer

    SPECIFICATION

    Sampling way
    Pump priming
    Resolution
    according to the range
    Precision
    ±5%FS
    Response time
    T90<30s
    Indicate way
    LCD display real-time concentration ,LED ,buzzer alarm
    Data storage
    Can store multiple sets of data
    Pressure range
    Atmospheric pressure
    Power supply
    Lithium battery (3.7V/3000Ah)
    Operating Current
    normal current:≤ 150mA; Alarm current: ≤ 200mA
    Operating Temperature
    -40 ℃ - 70 ℃
    Relative Humidity
    15% - 95%, non-condensing
    Storage Temperature
    -20 ℃ - 60 ℃
    Storage humidity
    ≤ 90%, no condensation
    Continuous work hours
    12hours
    Charge time
    6-8hours
    Dimensions
    228* 84 * 50.5mm
    Installation
    Handheld / Stand-in
    Weight
    0.55 kg
    Protection Class
    IP65

    APPLICATION

    The detector is widely used in petroleum, chemical industry, environmental protection, metallurgy, refining, biochemical medicine, agriculture, fire control, archaeology and other industries and places that need safety detection of toxic and harmful, explosion prevention.


    The detector can effectively predict the concentration of dangerous gas alarm, to ensure that the safety of staff life is not threatened, production equipment is not lost.


    City Sensor 3000MAh Oxygen Portable O2 Gas Detector Analyzer

    Quality City Sensor 3000MAh Oxygen Portable O2 Gas Detector Analyzer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing HiYi Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)